Structure-retention index relationship on polar columns, J. GHS Hazard and Precautionary Statements. It is a polycyclic aromatic hydrocarbon (PAH)-which are a large group of organic compounds occurring in groups of two or more. and g.c.-m.s. Temperature-programmed retention indices for GC and GC-MS of hydrocarbon fuels and simulated distillation GC of heavy oils, in Analytical advances for hydrocarbon research, Hsu,C.S., ed(s), Kluwer Academic/Plenum Publishers, New York, 2003, 147-193. ass: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; Heat rate: 4 K/min; Start T: 40 C; End T: 310 C; CAS no: 85018; Active phase: DB-5; Carrier gas: He; Phase thickness: 0.25 um; Data type: Linear RI; Authors: Lai, W.-C.; Song, C., Temperature-programmed retention indices for g.c. Molecular Formula: C14D10, Molecular Weight: 188.29 Molecular Formula: C14D10, Molecular Weight: 188.29 Choose a Store CopyCopied, Validated by Experts, Validated by Users, Non-Validated, Removed by Users, Predicted data is generated using the ACD/Labs Percepta Platform - PhysChem Module, Predicted data is generated using the US Environmental Protection Agency’s EPISuite™, Click to predict properties on the Chemicalize site, For medical information relating to Covid-19, please consult the. ; Moradpour, A.; Balavoine, G.; Kagan, H.; Martin, R.H.; Deblecker, M., Chromatographie en phase vapeur d'helicenes et de diaryl-1,2 ethylenes, J. Temperature-programmed retention indices for GC and GC-MS of hydrocarbon fuels and simulated distillation GC of heavy oils, in Analytical advances for hydrocarbon research, Hsu,C.S., ed(s), Kluwer Academic/Plenum Publishers, New York, 2003, 147-193. ass: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; Heat rate: 10 K/min; Start T: 50 C; End T: 300 C; CAS no: 85018; Active phase: HP-5MS; Phase thickness: 0.25 um; Data type: Linear RI; Authors: Nahir, T.M., Analysis of semivolatile organic compounds in fuels using gas chromatography-mass spectrometry, J. Chem. ; Kerr, A.A.; Lockington, J.N. CopyCopied, CSID:970, http://www.chemspider.com/Chemical-Structure.970.html (accessed 08:11, Nov 29, 2020) Chem., 51(6), 1979, 768-773. ass: Standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; Heat rate: 4 K/min; Start T: 60 C; End T: 290 C; CAS no: 85018; Active phase: OV-1; Carrier gas: Nitrogen; Data type: Normal alkane RI; Authors: Asif, M.; Fazeelat, T., Characterization of aromatic hydrocarbons in Dhurnal oil from Northen Indus Basin, J. Chem. Phenanthrene is nearly insoluble in water but is soluble in most low polarity organic solvents such as toluene, carbon tetrachloride, ether, chloroform, acetic acid and benzene. Chromatogr., 18(3), 2000, 241-246. ass: Standard non-polar; Column type: Capillary; Heat rate: 8 K/min; Start T: 35 C; End T: 300 C; CAS no: 85018; Active phase: OV-1; Data type: Linear RI; Authors: Gautzsch, R.; Zinn, P., Use of incremental models to estimate the retention indexes of aromatic compounds, Chromatographia, 43(3/4), 1996, 163-176. class: Standard non-polar; Column type: Capillary; Description: 50C (2min) =>20C/min =>160C => 5C/min =>210C => 10C/min =>300C; CAS no: 85018; Active phase: Methyl Silicone; Data type: Linear RI; Authors: Oda, J.; Ichikawa, S.; Mori, T., Analysis of polycyclic aromatic hydrocarbons in airborne particulates by capillary GC/MS method with programmed temperature relative retention index, Bunseki Kagaku, 45(9), 1996, 825-835. class: Standard non-polar; Column length: 3.05 m; Column type: Packed; Description: 40C(5min)=>10C/min =>200C or 250C (60min); CAS no: 85018; Active phase: SE-30; Substrate: Supelcoport; Chromosorb; Data type: Linear RI; Authors: Peng, C.T. Gas Chromatogr., , 1967, 103-106. ass: Standard polar; Column diameter: 0.25 mm; Column length: 60 m; Column type: Capillary; Heat rate: 2 K/min; Start T: 35 C; End T: 195 C; End time: 90 min; Start time: 5 min; CAS no: 85018; Active phase: Supelcowax-10; Carrier gas: He; Phase thickness: 0.25 um; Data type: Linear RI; Authors: Chung, H.Y. ; McDonald, T.J.; Reese, E.; Autenrieth, R.L., Estimation of selected physicochemical properties for methylated naphthalene compounds, Chemosphere, 52, 2003, 869-881. ass: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; Heat rate: 2 K/min; Start T: 40 C; End T: 310 C; CAS no: 85018; Active phase: DB-5; Carrier gas: He; Phase thickness: 0.25 um; Data type: Linear RI; Authors: Lai, W.-C.; Song, C., Temperature-programmed retention indices for g.c. ; Weis, U., Gas Chromatographic Determination of Polycyclic Aromatic Compounds with Fluorinated Analogues as Internal Standards, J. Chromatogr. Chim., 45(4), 2000, 313-318. ass: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 15 m; Column type: Capillary; Heat rate: 50 K/min; Start T: 50 C; End T: 320 C; End time: 1 min; Start time: 0.5 min; CAS no: 85018; Active phase: CP Sil 8 CB; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Vreuls, R.J.J. Phenanthrene is used in the synthesis of dyes, explosives and drugs. Ravatite represents a small group of organic minerals. J. ; Fang H.Z. Sci., 32, 2009, 660-670. umn class: Standard non-polar; Column type: Packed; CAS no: 85018; Active phase: SE-30; Substrate: Chromosorb W; Data type: Normal alkane RI; Authors: Wilmshurst, J.R., Gas-chromatographic analysis of polynuclear arenes, J. and g.c.-m.s. & Chromatogr. ; Gibson, E.S., Identification of polycyclic aromatic compounds in of poly-mutagenic emissions from steel casting, Biomed.

Italian Ice Brands, Tequila Lime Dipping Sauce, What Is A Niche In Business, H2o Full Form, Leggett And Platt Adjustable Base Reviews, Harley-davidson Heritage Softail For Sale Near Me, Can I Use Peeling Gel Everyday, Japanese Woodworking Tools,